Detail

BACK  EN  FR  DE  NL    Print

ES-TRIN, Article 8.08(2) - Bilge pumping and drainage system – interpretation of independent bilge pumps

Question:

How shall the term “independent bilge pumps” in Article 8.08(2) be interpreted?

If both pumps are driven by an electric motor, should they be supplied by different switchboard, main and emergency?

Answer:

“Independent bilge pumps” means pumps driven by different power sources. If the pumps are driven by an electric motor, the electric motors shall be supplied by different electrical power sources (switchboards).

CESNI/PT (23)m 60 rev.1, HR6
CESNI/PT (24) 17

Working group on technical requirements (CESNI/PT), Joint meeting of the inspection bodies, Bilge pump, independent, power sources